Industrial measurement — from sensor to report todd0808kimo9@hotmail.com 繁體中文
FA-F Series

Force Testing System

A high-resolution load-cell system for traction, friction and break-strength testing. 125 Hz sampling catches every transient peak, and each test ends with a report you can hand to a customer.

  • 50 kg – 2 t
  • 125 Hz
  • 24-bit
  • ±0.05 % FS
  • IP67
FieldAI

System architecture

Sensor, acquisition and software — integrated

The load cell’s mV/V signal is digitised by a 24-bit bridge DAQ and streamed over USB to the test software, which handles zeroing, calibration, quality control, logging and reporting.

FieldAI FA-LC-S 500 kg F Load cell mV/V bridge 125 Hz · 24-bit CH0 CH1 CH2 CH3 Bridge DAQ USB · RS485 · 4–20 mA 198.4 242.1 5.5% FieldAI Test Software Live view · Records · Reports

Key features

Designed for data you can defend

One-click zero & noise check

Zeroing also measures idle noise and sets a noise band, so no false loads at rest.

True raw peak

Filtering is for display only; peaks always come from unfiltered data — no clipped maxima.

Automatic plateau analysis

Finds the longest, steadiest loading plateau and reports mean, σ and CV.

Professional reports

Annotated chart, plain-language findings, report ID and sign-off — ready to hand over.

Multi-point calibration

≥ 5-point calibration with standard weights; parameters stored with every record.

Open raw data

Every sample saved to CSV / JSON with timestamps and quality flags; Excel-ready.

Interactive demo

Try the actual workflow

Simulated data, same steps as the real software: Zero → Start → Stop → Report.

SIMULATIONFieldAI ForceIdle
Live force0.00N
Peak—N
Mean (loaded)—N
CV stability—%
Elapsed0.0s
Press Zero to remove the load-cell offset, then Start.

Specifications

Models & system specifications

Model selection

ModelCapacityTypical noise σTypical use
FA-F5050 kg / 490 N≈ 0.005 kgfSeals, cables, fasteners
FA-F200200 kg / 1.96 kN≈ 0.02 kgfFixtures, rehab equipment
FA-F500500 kg / 4.9 kN≈ 0.05 kgfRobot traction, friction
FA-F2T2 t / 19.6 kN≈ 0.2 kgfVehicle pull, rigging, structures

System specifications

Load cellS-type, tension & compression, alloy steel, IP67, 2 mV/V rated output
Combined error≤ ±0.05 % FS (load cell, typical)
Acquisition4-channel bridge input, 24-bit, gain up to 128×, USB
Sampling rate125 Hz (8 ms), configurable 8 ms – 1 s
FilteringMoving average 40/80/160 ms; peak from raw data
MetricsPeak, rise time, loading rate, impulse, plateau mean / σ / CV, repeatability
OutputHTML report · CSV · JSON
SoftwareWindows 10 / 11 64-bit
UnitsN · kgf · lbf

Noise is the typical measured value after zeroing, unloaded, 8 ms sampling (σ 0.047 kgf measured on 500 kg range); other ranges scaled. Final specifications per quotation datasheet.

What’s in the box

  • S-type load cell with rod ends
  • 4-channel bridge DAQ with USB cable
  • Test software installer (lifetime updates)
  • Factory multi-point calibration report
  • Manual and operator training
  • Options: fixtures, pulling rig, anchors

Applications

Typical applications

LIVE 198.4 N
Robot traction

Legged or wheeled robots pull a fixed anchor; measure peak and sustained traction.

LIVE 0.62 μ
Floor friction

Drag across flooring at constant speed to measure static and kinetic friction.

LIVE 86.2 N
Seal & pull-off

Package seals, adhesives and connector pull-off with automatic pass/fail.

LIVE 1.52 kN
Cable & rigging break

Ramp to failure and capture the full load curve.

Have a measurement challenge? Talk to an engineer.

Tell us what and where you need to measure. We reply with a recommendation and quote within one business day.